Blame | Last modification | View Log | Download | RSS feed
EESchema-LIBRARY Version 2.3 Date: sab 02 mar 2013 11:51:57 CET#encoding utf-8## fotek_SSR#DEF fotek_SSR RLY 0 40 Y Y 1 F NF0 "RLY" 0 200 60 H V C CNNF1 "fotek_SSR" 0 -200 60 H V C CNNDRAWC -110 -100 10 0 1 0 FC -110 100 10 0 1 0 FC 115 -100 10 0 1 0 FC 115 100 10 0 1 0 FC 170 -100 10 0 1 0 FC 170 100 10 0 1 0 FS -200 150 200 -150 0 1 0 NS -180 120 -140 -120 0 1 0 NS 30 -60 70 60 0 1 0 NP 2 0 1 0 -180 -100 -200 -100 NP 2 0 1 0 -180 100 -200 100 NP 2 0 1 0 -110 -5 -110 25 NP 2 0 1 0 -110 100 -110 50 NP 2 0 1 0 -50 -100 -140 -100 NP 2 0 1 0 -50 -5 -50 25 NP 2 0 1 0 -50 100 -140 100 NP 2 0 1 0 -50 100 -50 50 NP 2 0 1 0 0 -20 0 20 NP 2 0 1 0 0 0 20 -20 NP 2 0 1 0 0 0 20 20 NP 2 0 1 0 50 -100 200 -100 NP 2 0 1 0 50 -60 50 -100 NP 2 0 1 0 50 60 50 100 NP 2 0 1 0 50 100 200 100 NP 2 0 1 0 115 -15 115 -100 NP 2 0 1 0 115 15 115 100 NP 2 0 1 0 150 -30 190 -30 NP 2 0 1 0 170 -50 170 -100 NP 2 0 1 0 170 80 170 65 NP 2 0 1 0 170 80 170 100 NP 2 0 1 0 190 -50 150 -50 NP 3 0 1 0 -95 25 -125 25 -125 25 NP 3 0 1 0 -85 30 -70 15 -70 15 NP 3 0 1 0 -85 50 -70 35 -70 35 NP 3 0 1 0 -35 25 -65 25 -65 25 NP 3 0 1 0 -25 30 -10 15 -10 15 NP 3 0 1 0 -25 50 -10 35 -10 35 NP 3 0 1 0 20 -20 20 -30 30 -30 NP 3 0 1 0 20 20 20 30 30 30 NP 3 0 1 0 105 -15 85 -35 70 -35 NP 3 0 1 0 115 -15 85 -15 85 -15 NP 3 0 1 0 115 15 145 15 145 15 NP 4 0 1 0 20 -20 10 -20 20 -10 20 -20 NP 5 0 1 0 -125 55 -95 55 -110 25 -125 55 -125 55 FP 5 0 1 0 -70 15 -75 15 -70 20 -70 15 -70 15 NP 5 0 1 0 -70 35 -75 35 -70 40 -70 35 -70 35 NP 5 0 1 0 -65 55 -35 55 -50 25 -65 55 -65 55 FP 5 0 1 0 -10 15 -15 15 -10 20 -10 15 -10 15 NP 5 0 1 0 -10 35 -15 35 -10 40 -10 35 -10 35 NP 5 0 1 0 85 15 115 15 100 -15 85 15 85 15 FP 5 0 1 0 115 -15 145 -15 130 15 115 -15 115 -15 FP 9 0 1 0 -110 -5 -120 -10 -100 -20 -120 -30 -100 -40 -120 -50 -100 -60 -110 -65 -110 -100 NP 9 0 1 0 -50 -5 -60 -10 -40 -20 -60 -30 -40 -40 -60 -50 -40 -60 -50 -65 -50 -100 NP 9 0 1 0 170 65 160 60 180 50 160 40 180 30 160 20 180 10 170 5 170 -30 NX ~ 1 300 100 100 L 50 50 1 1 PX ~ 2 300 -100 100 L 50 50 1 1 PX ~ 3 -300 100 100 R 50 50 1 1 PX ~ 4 -300 -100 100 R 50 50 1 1 PENDDRAWENDDEF## HSSR-8200#DEF HSSR-8200 RLY 0 40 Y Y 1 F NF0 "RLY" 0 200 60 H V C CNNF1 "HSSR-8200" 0 -200 60 H V C CNNDRAWC 60 0 5 0 1 0 NC 90 -100 5 0 1 0 NC 90 0 5 0 1 0 NC 90 100 5 0 1 0 NS 150 -150 -150 150 0 1 0 NP 3 0 1 0 -45 -15 -75 -15 -75 -15 NP 3 0 1 0 -35 -10 -20 -25 -20 -25 NP 3 0 1 0 -35 10 -20 -5 -20 -5 NP 3 0 1 0 75 55 105 55 105 55 NP 3 0 1 0 90 -55 90 -100 90 -100 NP 3 0 1 0 90 0 60 0 60 0 NP 3 0 1 0 90 25 90 -25 90 -25 NP 3 0 1 0 90 100 90 55 95 55 NP 3 0 1 0 105 -55 75 -55 75 -55 NP 4 0 1 0 -150 100 -60 100 -60 15 -60 15 NP 4 0 1 0 -60 -15 -60 -100 -150 -100 -150 -100 NP 4 0 1 0 45 -20 60 -20 60 0 60 0 NP 4 0 1 0 60 0 60 20 45 20 45 20 NP 5 0 1 0 -75 15 -45 15 -60 -15 -75 15 -75 15 FP 5 0 1 0 -20 -25 -25 -25 -20 -20 -20 -25 -20 -25 NP 5 0 1 0 -20 -5 -25 -5 -20 0 -20 -5 -20 -5 NP 5 0 1 0 20 40 0 40 0 -40 20 -40 20 -40 NP 5 0 1 0 45 -60 60 -60 60 -100 150 -100 150 -100 NP 5 0 1 0 45 60 60 60 60 100 150 100 150 100 NP 5 0 1 0 75 -25 105 -25 90 -55 75 -25 75 -25 FP 5 0 1 0 75 25 105 25 90 55 75 25 75 25 FP 6 0 1 0 20 -20 25 -20 25 -60 20 -60 20 -20 20 -20 NP 6 0 1 0 20 60 25 60 25 20 20 20 20 60 20 60 NP 6 0 1 0 45 -70 40 -70 40 -10 45 -10 45 -70 45 -70 NP 6 0 1 0 45 10 40 10 40 70 45 70 45 10 45 10 NX ~ 1 -250 100 100 R 50 50 1 1 PX ~ 2 -250 -100 100 R 50 50 1 1 PX ~ 3 250 -100 100 L 50 50 1 1 PX ~ 4 250 100 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_DK1a#DEF RELAY_DK1a RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_DK1a" 0 -235 60 H V C CNN$FPLISTrelay_DK1a$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C 70 -150 10 0 1 0 NP 2 0 1 0 -180 110 -140 110 NP 2 0 1 0 -160 130 -160 90 NP 2 0 1 0 130 110 170 110 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 -100 -100 -100 -100 -100 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -50 0 -70 0 -70 NP 3 0 1 0 0 -20 0 -40 0 -40 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 4 0 1 0 -60 -100 -40 -100 80 -60 80 -60 NX ~ 1 200 150 100 L 50 50 1 1 PX ~ 3 -200 -100 100 R 50 50 1 1 PX ~ 4 200 -150 100 L 50 50 1 1 PX ~ 6 -200 150 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_DK1a-L2#DEF RELAY_DK1a-L2 RLY 0 40 Y Y 1 F NF0 "RLY" 0 300 60 H V C CNNF1 "RELAY_DK1a-L2" 0 -285 60 H V C CNN$FPLISTrelay_DK1a-L2$ENDFPLISTDRAWA -45 100 15 1 1799 0 1 0 N -30 100 -60 100A -45 200 15 1 1799 0 1 0 N -30 200 -60 200A -15 100 15 1 1799 0 1 0 N 0 100 -30 100A -15 200 15 1 1799 0 1 0 N 0 200 -30 200A 15 100 15 1 1799 0 1 0 N 30 100 0 100A 15 200 15 1 1799 0 1 0 N 30 200 0 200A 45 100 15 1 1799 0 1 0 N 60 100 30 100A 45 200 15 1 1799 0 1 0 N 60 200 30 200C 70 -200 10 0 1 0 NC 100 150 10 0 1 0 FP 2 0 1 0 -180 60 -140 60 NP 2 0 1 0 -160 80 -160 40 NP 2 0 1 0 -100 200 -60 200 NP 2 0 1 0 130 110 170 110 NP 3 0 1 0 -70 80 -50 80 -50 80 NP 3 0 1 0 -60 -150 -100 -150 -100 -150 NP 3 0 1 0 -60 100 -100 100 -100 100 NP 3 0 1 0 -40 80 -20 80 -20 80 NP 3 0 1 0 -10 80 10 80 10 80 NP 3 0 1 0 0 -100 0 -120 0 -120 NP 3 0 1 0 0 -70 0 -90 0 -90 NP 3 0 1 0 0 -40 0 -60 0 -60 NP 3 0 1 0 0 -10 0 -30 0 -30 NP 3 0 1 0 0 20 0 0 0 0 NP 3 0 1 0 0 50 0 30 0 30 NP 3 0 1 0 0 80 0 60 0 60 NP 3 0 1 0 20 80 40 80 40 80 NP 3 0 1 0 50 80 70 80 70 80 NP 3 0 1 0 60 100 100 100 100 100 NP 3 0 1 0 100 -200 70 -200 70 -200 NP 3 0 1 0 100 100 100 200 60 200 NP 4 0 1 0 -60 -150 -40 -150 80 -110 80 -110 NX ~ 1 200 150 100 L 50 50 1 1 PX ~ 3 -200 -150 100 R 50 50 1 1 PX ~ 4 200 -200 100 L 50 50 1 1 PX ~ 5 -200 200 100 R 50 50 1 1 PX ~ 6 -200 100 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_DK1a1b#DEF RELAY_DK1a1b RLY 0 40 Y Y 1 F NF0 "RLY" 0 300 60 H V C CNNF1 "RELAY_DK1a1b" 0 -335 60 H V C CNN$FPLISTrelay_DK1a1b$ENDFPLISTDRAWA -45 200 15 1 1799 0 1 0 N -30 200 -60 200A -15 200 15 1 1799 0 1 0 N 0 200 -30 200A 15 200 15 1 1799 0 1 0 N 30 200 0 200A 45 200 15 1 1799 0 1 0 N 60 200 30 200C 70 -250 10 0 1 0 NC 70 -100 10 0 1 0 NP 2 0 1 0 -180 160 -140 160 NP 2 0 1 0 -160 180 -160 140 NP 2 0 1 0 -40 -200 -60 -200 NP 2 0 1 0 80 -240 -40 -200 NP 2 0 1 0 130 160 170 160 NP 3 0 1 0 -70 180 -50 180 -50 180 NP 3 0 1 0 -60 -200 -100 -200 -100 -200 NP 3 0 1 0 -60 -50 -100 -50 -100 -50 NP 3 0 1 0 -60 200 -100 200 -100 200 NP 3 0 1 0 -40 180 -20 180 -20 180 NP 3 0 1 0 -10 180 10 180 10 180 NP 3 0 1 0 0 -150 0 -170 0 -170 NP 3 0 1 0 0 -120 0 -140 0 -140 NP 3 0 1 0 0 -90 0 -110 0 -110 NP 3 0 1 0 0 -60 0 -80 0 -80 NP 3 0 1 0 0 0 0 -20 0 -20 NP 3 0 1 0 0 30 0 10 0 10 NP 3 0 1 0 0 60 0 40 0 40 NP 3 0 1 0 0 90 0 70 0 70 NP 3 0 1 0 0 120 0 100 0 100 NP 3 0 1 0 0 150 0 130 0 130 NP 3 0 1 0 0 180 0 160 0 160 NP 3 0 1 0 20 180 40 180 40 180 NP 3 0 1 0 50 180 70 180 70 180 NP 3 0 1 0 60 200 100 200 100 200 NP 3 0 1 0 100 -250 70 -250 70 -250 NP 3 0 1 0 100 -100 70 -100 70 -100 NP 4 0 1 0 -60 -50 -40 -50 80 -10 80 -10 NX ~ 1 200 200 100 L 50 50 1 1 PX ~ 3 -200 -50 100 R 50 50 1 1 PX ~ 4 200 -100 100 L 50 50 1 1 PX ~ 5 200 -250 100 L 50 50 1 1 PX ~ 6 -200 -200 100 R 50 50 1 1 PX ~ 8 -200 200 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_DK1a1b-L2#DEF RELAY_DK1a1b-L2 RLY 0 40 Y Y 1 F NF0 "RLY" 0 350 60 H V C CNNF1 "RELAY_DK1a1b-L2" 0 -385 60 H V C CNN$FPLISTrelay_DK1a1b-L2$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -45 250 15 1 1799 0 1 0 N -30 250 -60 250A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A -15 250 15 1 1799 0 1 0 N 0 250 -30 250A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 15 250 15 1 1799 0 1 0 N 30 250 0 250A 45 150 15 1 1799 0 1 0 N 60 150 30 150A 45 250 15 1 1799 0 1 0 N 60 250 30 250C 70 -300 10 0 1 0 NC 70 -150 10 0 1 0 NC 100 200 10 0 1 0 FP 2 0 1 0 -180 110 -140 110 NP 2 0 1 0 -160 130 -160 90 NP 2 0 1 0 -100 250 -60 250 NP 2 0 1 0 -40 -250 -60 -250 NP 2 0 1 0 80 -290 -40 -250 NP 2 0 1 0 130 160 170 160 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 -250 -100 -250 -100 -250 NP 3 0 1 0 -60 -100 -100 -100 -100 -100 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -200 0 -220 0 -220 NP 3 0 1 0 0 -170 0 -190 0 -190 NP 3 0 1 0 0 -140 0 -160 0 -160 NP 3 0 1 0 0 -110 0 -130 0 -130 NP 3 0 1 0 0 -50 0 -70 0 -70 NP 3 0 1 0 0 -20 0 -40 0 -40 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -300 70 -300 70 -300 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 150 100 250 60 250 NP 4 0 1 0 -60 -100 -40 -100 80 -60 80 -60 NX ~ 1 200 200 100 L 50 50 1 1 PX ~ 3 -200 -100 100 R 50 50 1 1 PX ~ 4 200 -150 100 L 50 50 1 1 PX ~ 5 200 -300 100 L 50 50 1 1 PX ~ 6 -200 -250 100 R 50 50 1 1 PX ~ 7 -200 250 100 R 50 50 1 1 PX ~ 8 -200 150 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_DK2a#DEF RELAY_DK2a RLY 0 40 Y Y 1 F NF0 "RLY" 0 300 60 H V C CNNF1 "RELAY_DK2a" 0 -335 60 H V C CNN$FPLISTrelay_DK2a$ENDFPLISTDRAWA -45 200 15 1 1799 0 1 0 N -30 200 -60 200A -15 200 15 1 1799 0 1 0 N 0 200 -30 200A 15 200 15 1 1799 0 1 0 N 30 200 0 200A 45 200 15 1 1799 0 1 0 N 60 200 30 200C 70 -250 10 0 1 0 NC 70 -100 10 0 1 0 NP 2 0 1 0 -180 160 -140 160 NP 2 0 1 0 -160 180 -160 140 NP 2 0 1 0 130 160 170 160 NP 3 0 1 0 -70 180 -50 180 -50 180 NP 3 0 1 0 -60 -200 -100 -200 -100 -200 NP 3 0 1 0 -60 -50 -100 -50 -100 -50 NP 3 0 1 0 -60 200 -100 200 -100 200 NP 3 0 1 0 -40 180 -20 180 -20 180 NP 3 0 1 0 -10 180 10 180 10 180 NP 3 0 1 0 0 -150 0 -170 0 -170 NP 3 0 1 0 0 -120 0 -140 0 -140 NP 3 0 1 0 0 -90 0 -110 0 -110 NP 3 0 1 0 0 -60 0 -80 0 -80 NP 3 0 1 0 0 0 0 -20 0 -20 NP 3 0 1 0 0 30 0 10 0 10 NP 3 0 1 0 0 60 0 40 0 40 NP 3 0 1 0 0 90 0 70 0 70 NP 3 0 1 0 0 120 0 100 0 100 NP 3 0 1 0 0 150 0 130 0 130 NP 3 0 1 0 0 180 0 160 0 160 NP 3 0 1 0 20 180 40 180 40 180 NP 3 0 1 0 50 180 70 180 70 180 NP 3 0 1 0 60 200 100 200 100 200 NP 3 0 1 0 100 -250 70 -250 70 -250 NP 3 0 1 0 100 -100 70 -100 70 -100 NP 4 0 1 0 -60 -200 -40 -200 80 -160 80 -160 NP 4 0 1 0 -60 -50 -40 -50 80 -10 80 -10 NX ~ 1 200 200 100 L 50 50 1 1 PX ~ 3 -200 -50 100 R 50 50 1 1 PX ~ 4 200 -100 100 L 50 50 1 1 PX ~ 5 200 -250 100 L 50 50 1 1 PX ~ 6 -200 -200 100 R 50 50 1 1 PX ~ 8 -200 200 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_DK2a-L2#DEF RELAY_DK2a-L2 RLY 0 40 Y Y 1 F NF0 "RLY" 0 350 60 H V C CNNF1 "RELAY_DK2a-L2" 0 -385 60 H V C CNN$FPLISTrelay_DK2a-L2$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -45 250 15 1 1799 0 1 0 N -30 250 -60 250A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A -15 250 15 1 1799 0 1 0 N 0 250 -30 250A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 15 250 15 1 1799 0 1 0 N 30 250 0 250A 45 150 15 1 1799 0 1 0 N 60 150 30 150A 45 250 15 1 1799 0 1 0 N 60 250 30 250C 70 -300 10 0 1 0 NC 70 -150 10 0 1 0 NC 100 200 10 0 1 0 FP 2 0 1 0 -180 110 -140 110 NP 2 0 1 0 -160 130 -160 90 NP 2 0 1 0 -100 250 -60 250 NP 2 0 1 0 130 160 170 160 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 -250 -100 -250 -100 -250 NP 3 0 1 0 -60 -100 -100 -100 -100 -100 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -200 0 -220 0 -220 NP 3 0 1 0 0 -170 0 -190 0 -190 NP 3 0 1 0 0 -140 0 -160 0 -160 NP 3 0 1 0 0 -110 0 -130 0 -130 NP 3 0 1 0 0 -50 0 -70 0 -70 NP 3 0 1 0 0 -20 0 -40 0 -40 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -300 70 -300 70 -300 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 150 100 250 60 250 NP 4 0 1 0 -60 -250 -40 -250 80 -210 80 -210 NP 4 0 1 0 -60 -100 -40 -100 80 -60 80 -60 NX ~ 1 200 200 100 L 50 50 1 1 PX ~ 3 -200 -100 100 R 50 50 1 1 PX ~ 4 200 -150 100 L 50 50 1 1 PX ~ 5 200 -300 100 L 50 50 1 1 PX ~ 6 -200 -250 100 R 50 50 1 1 PX ~ 7 -200 250 100 R 50 50 1 1 PX ~ 8 -200 150 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_DPDT#DEF RELAY_DPDT RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_DPDT" 0 -385 60 H V C CNNDRAWA -45 200 15 1 1799 0 1 0 N -30 200 -60 200A -15 200 15 1 1799 0 1 0 N 0 200 -30 200A 15 200 15 1 1799 0 1 0 N 30 200 0 200A 45 200 15 1 1799 0 1 0 N 60 200 30 200C 70 -250 10 0 1 0 NC 70 -150 10 0 1 0 NC 70 -50 10 0 1 0 NC 70 50 10 0 1 0 NP 3 0 1 0 -70 180 -50 180 -50 180 NP 3 0 1 0 -60 -200 -100 -200 -100 -200 NP 3 0 1 0 -60 0 -100 0 -100 0 NP 3 0 1 0 -60 200 -100 200 -100 200 NP 3 0 1 0 -40 180 -20 180 -20 180 NP 3 0 1 0 -10 180 10 180 10 180 NP 3 0 1 0 0 -170 0 -185 0 -185 NP 3 0 1 0 0 -140 0 -160 0 -160 NP 3 0 1 0 0 30 0 15 0 15 NP 3 0 1 0 0 60 0 40 0 40 NP 3 0 1 0 0 90 0 70 0 70 NP 3 0 1 0 0 120 0 100 0 100 NP 3 0 1 0 0 150 0 130 0 130 NP 3 0 1 0 0 180 0 160 0 160 NP 3 0 1 0 20 180 40 180 40 180 NP 3 0 1 0 50 180 70 180 70 180 NP 3 0 1 0 60 200 100 200 100 200 NP 3 0 1 0 100 -250 70 -250 70 -250 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 -50 70 -50 70 -50 NP 3 0 1 0 100 50 70 50 70 50 NP 4 0 1 0 -60 -200 -40 -200 80 -160 80 -160 NP 4 0 1 0 -60 0 -40 0 80 40 80 40 NX ~ 1 200 200 100 L 50 50 1 1 PX ~ 2 200 50 100 L 50 50 1 1 PX ~ 3 -200 0 100 R 50 50 1 1 PX ~ 4 200 -50 100 L 50 50 1 1 PX ~ 5 200 -250 100 L 50 50 1 1 PX ~ 6 -200 -200 100 R 50 50 1 1 PX ~ 7 200 -150 100 L 50 50 1 1 PX ~ 8 -200 200 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_GQ#DEF RELAY_GQ RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_GQ" 0 -385 60 H V C CNNDRAWA -45 200 15 1 1799 0 1 0 N -30 200 -60 200A -15 200 15 1 1799 0 1 0 N 0 200 -30 200A 15 200 15 1 1799 0 1 0 N 30 200 0 200A 45 200 15 1 1799 0 1 0 N 60 200 30 200C 70 -250 10 0 1 0 NC 70 -150 10 0 1 0 NC 70 -50 10 0 1 0 NC 70 50 10 0 1 0 NP 3 0 1 0 -70 180 -50 180 -50 180 NP 3 0 1 0 -60 -200 -100 -200 -100 -200 NP 3 0 1 0 -60 0 -100 0 -100 0 NP 3 0 1 0 -60 200 -100 200 -100 200 NP 3 0 1 0 -40 180 -20 180 -20 180 NP 3 0 1 0 -10 180 10 180 10 180 NP 3 0 1 0 0 -170 0 -185 0 -185 NP 3 0 1 0 0 -140 0 -160 0 -160 NP 3 0 1 0 0 30 0 15 0 15 NP 3 0 1 0 0 60 0 40 0 40 NP 3 0 1 0 0 90 0 70 0 70 NP 3 0 1 0 0 120 0 100 0 100 NP 3 0 1 0 0 150 0 130 0 130 NP 3 0 1 0 0 180 0 160 0 160 NP 3 0 1 0 20 180 40 180 40 180 NP 3 0 1 0 50 180 70 180 70 180 NP 3 0 1 0 60 200 100 200 100 200 NP 3 0 1 0 100 -250 70 -250 70 -250 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 -50 70 -50 70 -50 NP 3 0 1 0 100 50 70 50 70 50 NP 4 0 1 0 -60 -200 -40 -200 80 -160 80 -160 NP 4 0 1 0 -60 0 -40 0 80 40 80 40 NX ~ 1 200 200 100 L 50 50 1 1 PX ~ 2 200 50 100 L 50 50 1 1 PX ~ 3 -200 0 100 R 50 50 1 1 PX ~ 4 200 -50 100 L 50 50 1 1 PX ~ 5 200 -250 100 L 50 50 1 1 PX ~ 6 -200 -200 100 R 50 50 1 1 PX ~ 7 200 -150 100 L 50 50 1 1 PX ~ 8 -200 200 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_HB#DEF RELAY_HB RLY 0 40 Y Y 1 F NF0 "RLY" 0 350 60 H V C CNNF1 "RELAY_HB" 0 -335 60 H V C CNN$FPLISTrelay_HB$ENDFPLISTDRAWA -45 250 15 1 1799 0 1 0 N -30 250 -60 250A -15 250 15 1 1799 0 1 0 N 0 250 -30 250A 15 250 15 1 1799 0 1 0 N 30 250 0 250A 45 250 15 1 1799 0 1 0 N 60 250 30 250C 70 -250 10 0 1 0 NC 70 -150 10 0 1 0 NC 70 -50 10 0 1 0 NC 70 50 10 0 1 0 NP 3 0 1 0 -70 230 -50 230 -50 230 NP 3 0 1 0 -60 -200 -100 -200 -100 -200 NP 3 0 1 0 -60 0 -100 0 -100 0 NP 3 0 1 0 -60 250 -100 250 -100 250 NP 3 0 1 0 -40 230 -20 230 -20 230 NP 3 0 1 0 -10 230 10 230 10 230 NP 3 0 1 0 0 -160 0 -180 0 -180 NP 3 0 1 0 0 -130 0 -150 0 -150 NP 3 0 1 0 0 -100 0 -120 0 -120 NP 3 0 1 0 0 -70 0 -90 0 -90 NP 3 0 1 0 0 -40 0 -60 0 -60 NP 3 0 1 0 0 -10 0 -30 0 -30 NP 3 0 1 0 0 20 0 0 0 0 NP 3 0 1 0 0 50 0 30 0 30 NP 3 0 1 0 0 80 0 60 0 60 NP 3 0 1 0 0 110 0 90 0 90 NP 3 0 1 0 0 140 0 120 0 120 NP 3 0 1 0 0 170 0 150 0 150 NP 3 0 1 0 0 200 0 180 0 180 NP 3 0 1 0 0 230 0 210 0 210 NP 3 0 1 0 20 230 40 230 40 230 NP 3 0 1 0 50 230 70 230 70 230 NP 3 0 1 0 60 250 100 250 100 250 NP 3 0 1 0 100 -250 70 -250 70 -250 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 -50 70 -50 70 -50 NP 3 0 1 0 100 50 70 50 70 50 NP 4 0 1 0 -60 -200 -40 -200 80 -160 80 -160 NP 4 0 1 0 -60 0 -40 0 80 40 80 40 NX ~ 1 200 50 100 L 50 50 1 1 PX ~ 2 200 -50 100 L 50 50 1 1 PX ~ 3 -200 250 100 R 50 50 1 1 PX ~ 8 -200 0 100 R 50 50 1 1 PX ~ 9 -200 -200 100 R 50 50 1 1 PX ~ 14 200 250 100 L 50 50 1 1 PX ~ 15 200 -250 100 L 50 50 1 1 PX ~ 16 200 -150 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_PE#DEF RELAY_PE RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_PE" 0 -150 60 H V C CNNDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C 70 -100 10 0 1 0 NC 70 0 10 0 1 0 NP 2 0 1 0 -40 -50 -100 -50 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 -50 80 -90 80 -90 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -20 0 -35 0 -35 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -100 70 -100 70 -100 NP 3 0 1 0 100 0 70 0 70 0 NX ~ 1 -200 150 100 R 50 50 1 1 PX ~ 2 200 150 100 L 50 50 1 1 PX ~ 11 -200 -50 100 R 50 50 1 1 PX ~ 12 200 -100 100 L 50 50 1 1 PX ~ 14 200 0 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_RT1#DEF RELAY_RT1 RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_RT1" 0 -235 60 H V C CNN$FPLISTrelay_RT1$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C 70 -150 10 0 1 0 NC 70 -50 10 0 1 0 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 -100 -100 -100 -100 -100 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -50 0 -70 0 -70 NP 3 0 1 0 0 -20 0 -40 0 -40 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 -50 70 -50 70 -50 NP 4 0 1 0 -60 -100 -40 -100 80 -60 80 -60 NX ~ 1 200 150 100 L 50 50 1 1 PX ~ 2 -200 150 100 R 50 50 1 1 PX ~ 11 200 -50 100 L 50 50 1 1 PX ~ 12 -200 -100 100 R 50 50 1 1 PX ~ 14 200 -150 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_SPDT#DEF RELAY_SPDT RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_SPDT" 0 -150 60 H V C CNNDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C 70 -100 10 0 1 0 NC 70 0 10 0 1 0 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 -50 -60 -50 -60 -50 NP 3 0 1 0 -40 -50 80 -90 80 -90 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -20 0 -35 0 -35 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -100 70 -100 70 -100 NP 3 0 1 0 100 0 70 0 70 0 NP 5 0 1 0 -100 0 -60 0 -60 -100 -100 -100 -100 -100 NX ~ 1 -200 0 100 R 50 50 1 1 PX ~ 4 200 150 100 L 50 50 1 1 PX ~ 5 200 0 100 L 50 50 1 1 PX ~ 6 200 -100 100 L 50 50 1 1 PX ~ 7 -200 150 100 R 50 50 1 1 PX ~ 10 -200 -100 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_SY#DEF RELAY_SY RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_SY" 0 -235 60 H V C CNN$FPLISTrelay_SY$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C -100 -100 10 0 1 0 FC 70 -150 10 0 1 0 NC 70 -50 10 0 1 0 NP 2 0 1 0 -100 -50 -100 -150 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 -100 -100 -100 -100 -100 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -50 0 -70 0 -70 NP 3 0 1 0 0 -20 0 -40 0 -40 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 -50 70 -50 70 -50 NP 4 0 1 0 -60 -100 -40 -100 80 -60 80 -60 NX ~ 1 -200 -50 100 R 50 50 1 1 PX ~ 4 -200 150 100 R 50 50 1 1 PX ~ 5 200 -150 100 L 50 50 1 1 PX ~ 6 200 -50 100 L 50 50 1 1 PX ~ 7 200 150 100 L 50 50 1 1 PX ~ 10 -200 -150 100 R 50 50 1 1 PENDDRAWENDDEF## RELAY_T9AS1x1#DEF RELAY_T9AS1x1 RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_T9AS1x1" 0 -150 60 H V C CNN$FPLISTrelay_T9AS1x1$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C 70 0 10 0 1 0 NP 2 0 1 0 -40 -50 -100 -50 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 -50 80 -90 80 -90 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -20 0 -35 0 -35 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 0 70 0 70 0 NX ~ 1 -200 150 100 R 50 50 1 1 PX ~ 2 200 150 100 L 50 50 1 1 PX ~ 3 -200 -50 100 R 50 50 1 1 PX ~ 4 200 0 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_T9AS2x1#DEF RELAY_T9AS2x1 RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_T9AS2x1" 0 -150 60 H V C CNN$FPLISTrelay_T9AS2x1$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C 70 -100 10 0 1 0 NP 2 0 1 0 -40 -50 -100 -50 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 -50 80 -90 80 -90 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -20 0 -35 0 -35 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -100 70 -100 70 -100 NX ~ 1 -200 150 100 R 50 50 1 1 PX ~ 2 200 150 100 L 50 50 1 1 PX ~ 3 -200 -50 100 R 50 50 1 1 PX ~ 5 200 -100 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_T9AS5x1#DEF RELAY_T9AS5x1 RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_T9AS5x1" 0 -150 60 H V C CNN$FPLISTrelay_T9AS5x1$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C 70 -100 10 0 1 0 NC 70 0 10 0 1 0 NP 2 0 1 0 -40 -50 -100 -50 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 -50 80 -90 80 -90 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -20 0 -35 0 -35 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -100 70 -100 70 -100 NP 3 0 1 0 100 0 70 0 70 0 NX ~ 1 -200 150 100 R 50 50 1 1 PX ~ 2 200 150 100 L 50 50 1 1 PX ~ 3 -200 -50 100 R 50 50 1 1 PX ~ 4 200 0 100 L 50 50 1 1 PX ~ 5 200 -100 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_V23042#DEF RELAY_V23042 RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_V23042" 0 -335 60 H V C CNN$FPLISTrelay_V23042$ENDFPLISTDRAWA -45 200 15 1 1799 0 1 0 N -30 200 -60 200A -15 200 15 1 1799 0 1 0 N 0 200 -30 200A 15 200 15 1 1799 0 1 0 N 30 200 0 200A 45 200 15 1 1799 0 1 0 N 60 200 30 200C 70 -250 10 0 1 0 NC 70 -150 10 0 1 0 NC 70 -50 10 0 1 0 NC 70 50 10 0 1 0 NP 2 0 1 0 -150 180 -150 140 NP 2 0 1 0 -130 160 -170 160 NP 2 0 1 0 170 160 130 160 NP 3 0 1 0 -70 180 -50 180 -50 180 NP 3 0 1 0 -60 -200 -100 -200 -100 -200 NP 3 0 1 0 -60 0 -100 0 -100 0 NP 3 0 1 0 -60 200 -100 200 -100 200 NP 3 0 1 0 -40 180 -20 180 -20 180 NP 3 0 1 0 -10 180 10 180 10 180 NP 3 0 1 0 0 -170 0 -185 0 -185 NP 3 0 1 0 0 -140 0 -160 0 -160 NP 3 0 1 0 0 30 0 15 0 15 NP 3 0 1 0 0 60 0 40 0 40 NP 3 0 1 0 0 90 0 70 0 70 NP 3 0 1 0 0 120 0 100 0 100 NP 3 0 1 0 0 150 0 130 0 130 NP 3 0 1 0 0 180 0 160 0 160 NP 3 0 1 0 20 180 40 180 40 180 NP 3 0 1 0 50 180 70 180 70 180 NP 3 0 1 0 60 200 100 200 100 200 NP 3 0 1 0 100 -250 70 -250 70 -250 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 -50 70 -50 70 -50 NP 3 0 1 0 100 50 70 50 70 50 NP 4 0 1 0 -60 -200 -40 -200 80 -160 80 -160 NP 4 0 1 0 -60 0 -40 0 80 40 80 40 NX ~ 1 -200 200 100 R 50 50 1 1 PX ~ 4 -200 0 100 R 50 50 1 1 PX ~ 6 200 50 100 L 50 50 1 1 PX ~ 8 200 -50 100 L 50 50 1 1 PX ~ 9 200 -250 100 L 50 50 1 1 PX ~ 11 200 -150 100 L 50 50 1 1 PX ~ 13 -200 -200 100 R 50 50 1 1 PX ~ 16 200 200 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_V23042-B2#DEF RELAY_V23042-B2 RLY 0 40 Y Y 1 F NF0 "RLY" 0 350 60 H V C CNNF1 "RELAY_V23042-B2" 0 -385 60 H V C CNN$FPLISTrelay_v23042-b2$ENDFPLISTDRAWT 0 0 180 20 0 0 0 RESET Normal 0 C CT 0 0 280 20 0 0 0 SET Normal 0 C CA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -45 250 15 1 1799 0 1 0 N -30 250 -60 250A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A -15 250 15 1 1799 0 1 0 N 0 250 -30 250A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 15 250 15 1 1799 0 1 0 N 30 250 0 250A 45 150 15 1 1799 0 1 0 N 60 150 30 150A 45 250 15 1 1799 0 1 0 N 60 250 30 250C 70 -300 10 0 1 0 NC 70 -200 10 0 1 0 NC 70 -100 10 0 1 0 NC 70 0 10 0 1 0 NP 2 0 1 0 -150 130 -150 90 NP 2 0 1 0 -130 110 -170 110 NP 2 0 1 0 170 110 130 110 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 -250 -100 -250 -100 -250 NP 3 0 1 0 -60 -50 -100 -50 -100 -50 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -60 250 -100 250 -100 250 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -200 0 -220 0 -220 NP 3 0 1 0 0 -170 0 -190 0 -190 NP 3 0 1 0 0 -140 0 -160 0 -160 NP 3 0 1 0 0 -110 0 -130 0 -130 NP 3 0 1 0 0 -80 0 -100 0 -100 NP 3 0 1 0 0 -50 0 -70 0 -70 NP 3 0 1 0 0 -20 0 -40 0 -40 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 60 250 100 250 100 250 NP 3 0 1 0 100 -300 70 -300 70 -300 NP 3 0 1 0 100 -200 70 -200 70 -200 NP 3 0 1 0 100 -100 70 -100 70 -100 NP 3 0 1 0 100 0 70 0 70 0 NP 4 0 1 0 -60 -250 -40 -250 80 -210 80 -210 NP 4 0 1 0 -60 -50 -40 -50 80 -10 80 -10 NX ~ 1 -200 250 100 R 50 50 1 1 PX ~ 2 -200 150 100 R 50 50 1 1 PX ~ 4 -200 -50 100 R 50 50 1 1 PX ~ 6 200 0 100 L 50 50 1 1 PX ~ 8 200 -100 100 L 50 50 1 1 PX ~ 9 200 -300 100 L 50 50 1 1 PX ~ 11 200 -200 100 L 50 50 1 1 PX ~ 13 -200 -250 100 R 50 50 1 1 PX ~ 15 200 150 100 L 50 50 1 1 PX ~ 16 200 250 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_V23101-D0#DEF RELAY_V23101-D0 RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_V23101-D0" 0 -235 60 H V C CNN$FPLISTrelay_V23101-D0$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C -100 -100 10 0 1 0 FC 70 -150 10 0 1 0 NC 70 -50 10 0 1 0 NP 2 0 1 0 -100 -50 -100 -150 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 -100 -100 -100 -100 -100 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -50 0 -70 0 -70 NP 3 0 1 0 0 -20 0 -40 0 -40 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 -50 70 -50 70 -50 NP 4 0 1 0 -60 -100 -40 -100 80 -60 80 -60 NX ~ 1 200 -50 100 L 50 50 1 1 PX ~ 2 -200 150 100 R 50 50 1 1 PX ~ 6 -200 -50 100 R 50 50 1 1 PX ~ 7 -200 -150 100 R 50 50 1 1 PX ~ 11 200 150 100 L 50 50 1 1 PX ~ 12 200 -150 100 L 50 50 1 1 PENDDRAWENDDEF## RELAY_V23101-D1#DEF RELAY_V23101-D1 RLY 0 40 Y Y 1 F NF0 "RLY" 0 250 60 H V C CNNF1 "RELAY_V23101-D1" 0 -235 60 H V C CNN$FPLISTrelay_V23101-D1$ENDFPLISTDRAWA -45 150 15 1 1799 0 1 0 N -30 150 -60 150A -15 150 15 1 1799 0 1 0 N 0 150 -30 150A 15 150 15 1 1799 0 1 0 N 30 150 0 150A 45 150 15 1 1799 0 1 0 N 60 150 30 150C 70 -150 10 0 1 0 NC 70 -50 10 0 1 0 NP 3 0 1 0 -70 130 -50 130 -50 130 NP 3 0 1 0 -60 -100 -100 -100 -100 -100 NP 3 0 1 0 -60 150 -100 150 -100 150 NP 3 0 1 0 -40 130 -20 130 -20 130 NP 3 0 1 0 -10 130 10 130 10 130 NP 3 0 1 0 0 -50 0 -70 0 -70 NP 3 0 1 0 0 -20 0 -40 0 -40 NP 3 0 1 0 0 10 0 -10 0 -10 NP 3 0 1 0 0 40 0 20 0 20 NP 3 0 1 0 0 70 0 50 0 50 NP 3 0 1 0 0 100 0 80 0 80 NP 3 0 1 0 0 130 0 110 0 110 NP 3 0 1 0 20 130 40 130 40 130 NP 3 0 1 0 50 130 70 130 70 130 NP 3 0 1 0 60 150 100 150 100 150 NP 3 0 1 0 100 -150 70 -150 70 -150 NP 3 0 1 0 100 -50 70 -50 70 -50 NP 4 0 1 0 -60 -100 -40 -100 80 -60 80 -60 NX ~ 1 200 -50 100 L 50 50 1 1 PX ~ 2 -200 150 100 R 50 50 1 1 PX ~ 7 -200 -100 100 R 50 50 1 1 PX ~ 11 200 150 100 L 50 50 1 1 PX ~ 12 200 -150 100 L 50 50 1 1 PENDDRAWENDDEF##End Library